mika kuns 3462ca1355 fix(installer): read the persisted MCP port on update instead of the wizard default
RegisterMcpStep built the registration URL from ctx.ExternalMcpPort, which the
Update pipeline never repopulates from the existing installation, so any
update silently re-registered the wizard default (47822) even when
worker.config.json had a different port configured. InstallerWorkerConfig was
also missing external_mcp_port entirely, so the installer had no way to read
it back. Port 0 (external listener disabled) now skips registration instead
of pointing Claude at 127.0.0.1:0/mcp.